LAC Test Results / Actions
EMI/EMC (Instrument Level):
- Excessive Radiated/ Conducted Emissions (20 - 30 dB in Some Places).
- Insufficient Power Supply Filtering
- Additional Filter Assembly Mounted on EM
- Filter Reduces Excess Emissions to at Most 5 dB - Waiver Granted
- Components Destroyed During Conducted Susceptibility Test
- Incorrect Test Conditions
- Components Replaced
- Test Was not Repeated - Waiver Granted